Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1990 1
1993 2
1996 1
2001 1
2002 4
2003 4
2004 1
2005 3
2006 3
2007 2
2008 2
2009 2
2010 4
2011 5
2012 6
2013 10
2014 7
2015 9
2016 7
2017 4
2018 1
2019 4
2020 1
2021 8
2022 8
2023 6
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

97 results

Results by year

Filters applied: . Clear all
Page 1
Influence of Multiple Used Implant Drills on Their Cutting Performance and Fracture Resistance.
Alevizakos V, Mosch R, von See C. Alevizakos V, et al. Materials (Basel). 2023 Jul 27;16(15):5271. doi: 10.3390/ma16155271. Materials (Basel). 2023. PMID: 37569975 Free PMC article.
The drills were divided into four groups based on the cycle count, and the drilling time was measured. ...However, no significant differences were found for o3.75 mm and o4.25 mm drills, and drilling times also varied significantly among different d
The drills were divided into four groups based on the cycle count, and the drilling time was measured. ...However, no signific …
Reinforcing an immature tooth model using three different restorative materials.
Misar P, Hiremath H, Harinkhere C, Sonawane SS, Sharma V, Rana KS. Misar P, et al. Dent Res J (Isfahan). 2022 Mar 21;19:28. eCollection 2022. Dent Res J (Isfahan). 2022. PMID: 35432792 Free PMC article.
MATERIALS AND METHODS: In this in vitro study, 80 human maxillary permanent central incisors scheduled for periodontal extraction were collected, and an immature tooth model was prepared using a 3 mm twist drill. To simulate single-visit apical barrier, all the teeth were …
MATERIALS AND METHODS: In this in vitro study, 80 human maxillary permanent central incisors scheduled for periodontal extraction were colle …
K-wire pullout strength in hand surgery: Impact of diameter, threading length and drilling speed.
Tamiti L, Braymand S, Bahlouli N, Facca S, Sapa MC, Liverneaux P. Tamiti L, et al. Orthop Traumatol Surg Res. 2022 Dec;108(8):103248. doi: 10.1016/j.otsr.2022.103248. Epub 2022 Feb 15. Orthop Traumatol Surg Res. 2022. PMID: 35181514 Free article.
MATERIAL AND METHODS: The material comprised Sawbones (20 2050mm), K-wires (diameter 1.2mm, 1.5mm, 1.8mm; threading 0mm, 5mm, 10mm, 15mm), a universal chuck with T handle and a drill (speed 0, 320, 500, 830, 1,290rpm), and tensile testing machine and a digita …
MATERIAL AND METHODS: The material comprised Sawbones (20 2050mm), K-wires (diameter 1.2mm, 1.5mm, 1.8mm; threading 0mm, 5mm, 10mm, 15mm), a …
Experimental investigations of a manually versus an electrically driven skull drill for bedside usage.
Carolus A, Richter W, Fritzen CP, Schmieder K, Brenke C. Carolus A, et al. PLoS One. 2019 Apr 18;14(4):e0215171. doi: 10.1371/journal.pone.0215171. eCollection 2019. PLoS One. 2019. PMID: 30998712 Free PMC article.
BACKGROUND: Manual skull drilling is an old but in modern neurosurgery still established procedure which can be applied quickly and universally in emergency situations. ...Half of the holes were produced with a prototype electrical drilling machine of …
BACKGROUND: Manual skull drilling is an old but in modern neurosurgery still established procedure which can be applied quickly and …
Adhesion of individually formed fiber post adhesively luted with flowable short fiber composite.
Suni AO, Lassila LVJ, Tuokko JK, Garoushi S, Vallittu PK. Suni AO, et al. Biomater Investig Dent. 2023 May 11;10(1):2209593. doi: 10.1080/26415275.2023.2209593. eCollection 2023. Biomater Investig Dent. 2023. PMID: 37187569 Free PMC article.
This laboratory study aimed to measure the push-out bond strength of individually formed fiber-reinforced composite (FRC) post luted with flowable short fiber-reinforced composite (SFRC) and to evaluate the influence of post coating with light-cured adhesive. Post spaces (O 1.7 m …
This laboratory study aimed to measure the push-out bond strength of individually formed fiber-reinforced composite (FRC) post luted with fl …
Fracture Resistance of Molars With Simulated Strip Perforation Repaired With Different Calcium Silicate-Based Cements.
Kabtoleh A, Aljabban O, Alsayed Tolibah Y. Kabtoleh A, et al. Cureus. 2023 Jan 31;15(1):e34462. doi: 10.7759/cureus.34462. eCollection 2023 Jan. Cureus. 2023. PMID: 36874725 Free PMC article.
Materials and methods Seventy-five molars were instrumented to size #25 and taper 4%, irrigated with sodium hypochlorite and ethylenediaminetetraacetic acid (EDTA), dried, and then divided randomly into five groups (G1-G5): in G1, root canals were filled with gutta-percha and sea …
Materials and methods Seventy-five molars were instrumented to size #25 and taper 4%, irrigated with sodium hypochlorite and ethylenediamine …
Bonding between implant attachment pickup materials and CAD-CAM denture base material.
Panittaveekul M, Phasuk K, Levon J, Chu TG. Panittaveekul M, et al. J Prosthet Dent. 2021 Jul;126(1):102.e1-102.e7. doi: 10.1016/j.prosdent.2021.04.013. Epub 2021 May 21. J Prosthet Dent. 2021. PMID: 34024620
The material was cut into 25255-mm disks, and a O6.5-mm hole was drilled into the center of the disks. Six pickup materials from 3 groups were tested: composite resin with bonding agent (N=3, EZ PickUp, Quick Up, and Triad gel), composite resin without bonding agent (N=1, …
The material was cut into 25255-mm disks, and a O6.5-mm hole was drilled into the center of the disks. Six pickup materials from 3 gr …
Comparison of fracture resistance of fiber-reinforced post and core with different cementation techniques: in vitro study.
AlHelal AA, AlZaben AA, AlObaid SA, Bakhsh OY, AlSaiari HN, AlQahtani AS, AlNassar TM, Alsayed HD. AlHelal AA, et al. Eur Rev Med Pharmacol Sci. 2022 Dec;26(23):8832-8840. doi: 10.26355/eurrev_202212_30555. Eur Rev Med Pharmacol Sci. 2022. PMID: 36524502 Free article.
All included specimens received root canal treatment (RCT). Post-space preparation was done using Gates Glidden drills. Post space was standardized with 10 mm length, keeping 3 to 5 mm as an apical seal. ...All samples were subjected to pushing forces to measure the fractu …
All included specimens received root canal treatment (RCT). Post-space preparation was done using Gates Glidden drills. Post space wa …
The effect of different orthodontic mini-implant brands and geometry on primary stability (an in vitro study).
Abdalla KL, Ali Mahmood TM. Abdalla KL, et al. Heliyon. 2023 Sep 6;9(9):e19858. doi: 10.1016/j.heliyon.2023.e19858. eCollection 2023 Sep. Heliyon. 2023. PMID: 37809894 Free PMC article.
OBJECTIVES: To evaluate the primary stability of different sizes and brands of orthodontic mini-implants by optimizing the insertion torque value (ITV) and to clear out which one has the greatest primary stability among the most widely used mini-implants by orthodontists. METHODS …
OBJECTIVES: To evaluate the primary stability of different sizes and brands of orthodontic mini-implants by optimizing the insertion torque …
Drilling Strategies to Improve the Geometrical and Dimensional Accuracy of Deep through Holes Made in PA6 Alloy.
Bronis M, Miko E, Nozdrzykowski K. Bronis M, et al. Materials (Basel). 2022 Dec 22;16(1):110. doi: 10.3390/ma16010110. Materials (Basel). 2022. PMID: 36614449 Free PMC article.
This article shows how different drilling strategies may affect the geometrical and dimensional accuracy of deep through holes. The tests were conducted on a three-axis direct-drive turning center. The holes were drilled in cylindrical PA6 aluminum alloy specimens 3 …
This article shows how different drilling strategies may affect the geometrical and dimensional accuracy of deep through holes. The t …
97 results